A self-contained implementation of the logicle transform (Parks, Roederer & Moore, Cytometry A 2006), used as a replacement for flowWorkspace::flowjo_biexp() with the same channelRange/maxValue/pos/neg/widthBasis argument names, but with no hard-coded -1000 floor on widthBasis. Uses only base R (stats::uniroot() for a one-time scalar solve).

Usage

biexp.transform(
  channelRange = 4096,
  maxValue = 262144,
  pos = 4.5,
  neg = 0,
  widthBasis = -10,
  inverse = FALSE,
  newton.iter = 5L
)

Arguments

channelRange

numeric. Maximum value of the transformed (display) scale. Default 4096.

maxValue

numeric. Maximum value of the input (raw) scale. Default 262144.

pos

numeric. Number of positive decades spanned by the transform (M in the logicle parameterisation). Default 4.5.

neg

numeric. Must be 0; see Details.

widthBasis

numeric, negative. FlowJo-style width parameter; see Details for its relationship to the logicle W. Default -10.

inverse

logical. If TRUE, returns the inverse transform (display scale back to raw values) instead of the forward transform.

newton.iter

integer. Fixed number of vectorised Newton iterations used to solve the forward transform. Default 5 – the smallest value that reaches double-precision round-trip error across the ranges swept in testing. Has no effect on the inverse direction, which is closed-form. If a different pos/widthBasis combination needs more, the built-in residual check will warn rather than silently under-converge.

Value

A function mapping a numeric vector on the input scale to the transformed display scale (or the reverse, if inverse = TRUE).

Details

FlowJo's widthBasis is a legacy re-parameterisation of the logicle transform's width parameter W (in asymptotic decades): $$W = \log_{10}(-\mathrm{widthBasis}) / 2$$ The logicle transform requires \(0 < W \le M/2\), where M is pos. FlowJo's UI, and flowWorkspace::flowjo_biexp(), impose a hard floor of widthBasis = -1000 (W = 1.5) regardless of pos – a historical GUI choice, not a mathematical one. This function checks the real constraint against whatever pos you supply and errors with the exact numbers if it's violated.

Only neg = 0 is supported (the value used by every cytometer profile in this package). Extending to neg > 0 requires the shifted-origin form of the transform (GatingML 2.0's A parameter) and is deliberately left unimplemented until there's a concrete need for it and data to verify it against.

The forward direction (raw intensity -> display decade) has no closed form and is solved by Newton-Raphson, applied to the whole input vector at once for a fixed number of iterations (not a per-point loop), starting from asinh(x / (2 * a.scale)) – correct in the large-|x| limit and reasonable near zero. The inverse direction (display decade -> raw intensity) is closed-form.

References

Parks DR, Roederer M, Moore WA (2006). A new "Logicle" display method avoids deceptive effects of logarithmic scaling for low signals and compensated data. Cytometry A, 69(6):541-551.